Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
JACC Cardiovasc Interv ; 15(6): 590-598, 2022 03 28.
Article in English | MEDLINE | ID: covidwho-1747832

ABSTRACT

OBJECTIVES: The aim of this study was to determine the safety and efficacy of same-day discharge (SDD) after transcatheter aortic valve replacement (TAVR) during the COVID-19 pandemic. BACKGROUND: The COVID-19 pandemic has placed significant stress on health care systems worldwide. SDD in highly selected TAVR patients can facilitate the provision of essential cardiovascular care while managing competing COVID-19 resource demands. METHODS: Patient selection for SDD was at the discretion of the local multidisciplinary heart team, across 7 international sites. The primary outcome was a composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new permanent pacemaker (PPM) implantation. RESULTS: From March 2020 to August 2021, 124 of 2,100 patients who underwent elective transfemoral TAVR were selected for SDD. The average age was 78.9 ± 7.8 years, the median Society of Thoracic Surgeons score was 2.4 (IQR: 1.4-4.2), and 32.3% (n = 40) had preexisting PPMs. There were no major vascular complications, strokes, or deaths during the index admission. One patient (0.8%) required PPM implantation for complete heart block and was discharged the same day. No patient required a PPM between discharge home and 30-day follow-up. The composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new PPM at 30 days occurred in 5.7% patients (n = 6 of 106). CONCLUSIONS: SDD post-TAVR is safe and feasible in selected patients at low risk for adverse clinical events postdischarge. This strategy may have a potential role in highly selected patients even when the COVID-19 pandemic abates.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Transcatheter Aortic Valve Replacement , Aftercare , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Humans , Pandemics , Patient Discharge , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
2.
Clin Cardiol ; 44(10): 1344-1353, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1453560

ABSTRACT

BACKGROUND: The use of transcatheter aortic valve implantation (TAVI) for treating aortic stenosis (AS) has increased exponentially in recent years. Despite the availability of clinical practice guidelines for the management of valvular heart disease, disparities in quality of care (QoC) for TAVI patients remain widespread across Europe. Tailored QoC measures will help to reduce resource utilization and improve patient outcomes without compromising patient safety. Using a clear set of QoC measures, the BENCHMARK registry aims to document the progress that can be achieved if such tailored QoC measures are implemented. METHODS: The BENCHMARK registry (BENCHMARK) is a non-interventional, multicenter registry in patients with severe symptomatic AS undergoing TAVI with a 1- and 12-months follow-up. BENCHMARK will be conducted at 30 centers across Europe and will enroll a total of 2400 consecutive TAVI patients. Patients suffering from severe symptomatic AS who undergo TAVI with a balloon-expandable transcatheter aortic valve will be included. The registry will comprise four phases: (1) a retrospective baseline evaluation phase; (2) an education phase; (3) an implementation phase; and (4) a prospective effect documentation phase (prospective phase). The registry's primary objectives are to reduce the length of hospital stay and accelerate the post-procedural patient recovery pathway, but without compromising safety. The study started in April 2021 and has an estimated completion date of May 2023. DISCUSSION: BENCHMARK will establish QoC measures to reduce resource utilization, intensive care unit bed occupancy, and overall length of hospitalization with uncompromised patient safety post-TAVI (ClinicalTrials.gov Identifier: NCT04579445).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Benchmarking , Europe , Humans , Prospective Studies , Registries , Retrospective Studies , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL